2,2-Dichloro-1,1,1-trifluoroethane or HCFC-123 is considered as an alternative to CFC-11 in low pressure refrigeration/HVAC systems, and should not be used in foam blowing processes or solvent applications.

Its ozone depletion potential is ODP = 0.012, and global warming potential is GWP = 76. HCFC-123 will eventually be phased out under the current schedule of the Montreal Protocol, but can continue to be used in new HVAC equipment until 2020 in developed countries, and will still be produced for service use of HVAC equipment until 2030. Developing countries can use in new equipment until 2030, and can be produced for use in service until 2040.

HCFC-123 is used in large tonnage centrifugal chiller applications, and is the most efficient refrigerant currently in use in the marketplace for HVAC applications. HCFC-123 is also used as a testing agent for bypass leakage of carbon adsorbers in gas filtration systems, and as the primary chemical in Halotron I fire-extinguishing agent.[2]
Storage tanks carrying HCFC-123 should be a light grey. Isomers are 1,2-dichloro-1,1,2-trifluoroethane (R-123a) with CAS 354-23-4 and 1,1-dichloro-1,2,2-trifluoroethane (R-123b) with CAS 812-04-4.

HCFC 123 is the raw base material use to produce a halogeanated, safe/effective and environment friendly fire extinguishing chemical agent called "halotron I". It was introduce in early 1990's to replace the "banned" fire extinguishing agents like, Halon 1211 and BCF's, which were found to have a severe ozone depleting potentials. In contrast, hcfc 123 base fire extinguishing agents has a near zero ozone depletion potentials.
  • y0bd7c2386c11040820e374580ecb3cc36.jpg
  • 7e97ad1ca498995e7674d837f4f995b955.jpg

References
Article Rating

This article has been read 2176 times.

DISCLAIMER: All contents published on this website is for informational purposes only. In as much as we encourage write-ups to be originally written by the claimed authors, we might not be able to control those who will try to copy articles from other authors/writers. In view of the above, the owner and management of Safetyhow.com will not be liable for any loses, injuries, or damages from the display or use of the contents herein. Likewise, the owner and management will not be liable for any errors or omissions in the information stated. Furthermore, we highly recommend that any form of plagiarism or libel committed as a result or implication of the articles written by any specific author in this platform be reported to us immediately so that appropriate action will be given.